Home | E-Mail | Contact Us
Home About THIM Speech News Production Series R&D After-Sales Service Contact Us
Product Introduction
Epoxy Fiberglass Pultruded Panel

Epoxy Panel have high mechanical strength,low water absorption and good dieletric property .Be used in high voltage eletrical apparantus as construction parts of insulation.The products are widely used in dry transformer, high-voltage isolatian switch,reactor,cushion and pull-rod of the railway, tunnel and pit etc.

Epoxy Fiberglass Pultruded Panel

Epoxy-Phnolic Laminate Fiberglass Cloth Plate

Compliance:GB 1303.1-1998
Epoxy-phenolic laminate fiberglass cloth plate is E-glass as reinforcement, Epoxy-phenolic resin as matrix,formation through heat press.
This plate has high sthength,good dielectric property,used in motor driven,electric apparatus insulating structural parts,but also used in wet environment.
1 Technical Demand
1.1 Appearance:The surface must be smoothing,Don't allow air bubble,wrinckle,crack which hasn't defect as possible as,such as scratch,dent or hue isn't eveness,but allow few punctum,Plate edge must cut off tidy.
The edge face don't allow delaminatiom and crack
1.2 Dimension and Allowable Deviation
1.2.1 Length and Width See Table

Length and Width Allowable Deviation
£¾970~1970 25

1.2.2 Normal Thickness

Norminal Thickness Deviation Norminal Thickess Deviation
0.5 ¡À0.12 10 0.82
0.6 0.13 12 ¡À0.94
0.8 0.16 14 ¡À1.02
1.0 0.18 16 ¡À1.12
1.2 0.20 20 ¡À1.30
1.6 0.24 25 ¡À1.50
2.0 0.28 30 ¡À1.70
2.5 0.33 35 ¡À1.95
3.0 0.37 40 ¡À2.10
4.0 0.45 45 ¡À2.30
5.0 0.52 50 ¡À2.45
6.0 0.60 60 ¡À2.50
8.0 0.72 80 ¡À2.80

Product of non-norminal thickness may manufacture according to supplier and demander arrange ment.
1.3 Angularity See Table

Thickness Angularily
1000(Straightedge Length) 500(Straightedge Length)
3.0~6.0 ¡Ü10 ¡Ü2.5
£¾6.0~8.0 8 ¡Ü2.0
8.0 ¡Ü6 ¡Ü1.5

1.4 Machining:After laminate plale conduct sawing,drilling,lathe ginding,milling ete,which no crack and falling slag.
1.5 Physical and machanical property of laminate plate See Table

Number Test ltem Unit Indication Value
1 Density G/cm3 1.7~1.9
2 Martin Temperature Resistance   ¡æ ¡Ý200
3 Heat Stability ¡æ 200
4 Oil Resistance At Transformer oil,4h   £¾130
5 Water Absorption £¥ ¡Ü0.8
6 Flexural Strength of the Vertical to Layer Direction Longitudinal MPa 350
Transverse ¡Ý290
7 Tensile Strength Longitudinal   ¡Ý300
Transverse ¡Ý220
8 Impact strength(simple beam,no notch) Thickness 3~9.5mm Longitudinal KJ/m2 ¡Ý60
Transverse ¡Ý50
Thickness >9.5mm Longitudinal ¡Ý220
Transverse ¡Ý200
9 Adhesive Force N ¡Ý5600
10 Surface Resistivity Normality ¦¸ ¡Ý1.0¡Á1013
After Immersion Water,24h ¡Ý1.0¡Á1011
Product Introduction
Epoxy Fiberglass Rod
Epoxy Fiberglass Winding Tube
Epoxy Fiberglass Punthare Wall Dud
FRP Laininate Panel
FRP Grating
FRP Insutation Ladder
FRP Handrail
FRP Handle
All Variety Of FRP Profiles
Composite Insulator
Recommendation Product:
  • Epoxy Fiberglass Rod
  • Epoxy Fiberglass Winding Tube
  • FRP Grating
  • Composite Insulator
  • FRP Laininate Panel